首页/文章/ 详情

RED-ACT: 9月8日四川内江市威远县5.4级地震破坏力分析

1年前浏览449


RED-ACT Report

Real-time Earthquake Damage Assessment using City-scale Time-history analysis

Sep. 8, M5.4 Weiyuan County, Sichuan Province Earthquake

Research group of Xinzheng Lu at Tsinghua University (luxz@tsinghua.edu.cn)

First reported at 8:30, Sep. 8, 2019 (Beijing Time, UTC +8)

Acknowledgments and Disclaimer

The authors are grateful for the data provided by Sichuan Earthquake Bureau and China Earthquake Network Center (CENC). This analysis is for research only. The actual damage resulting from the earthquake should be determined according to the site investigation.

Scientific background of this report can be found at: 

http://www.luxinzheng.net/rr.htm


1. Introduction to the earthquake event

At 06:42 Sep. 8 2019 (Local Time, UTC +8), an M 5.4 earthquake occurred in Weiyuan County, Sichuan Province. The epicenter was located at 104.79 29.55, with a depth of 10.0 km. 


2. Recorded ground motions

3 ground motions near to epicenter of this earthquake were analyzed. The names and locations of the stations can be found Table 1. The maximal recorded peak ground acceleration (PGA) is 15.8 cm/s/s. The corresponding response spectra in comparison with the design spectra specified in the Chinese Code for Seismic Design of Buildings are shown in Figure 1.

 

Figure 1 Response spectra of the recorded ground motions with maximal PGA


3. Damage analysis of the target region subjected to the recorded ground motions

Using the real-time ground motions obtained from the strong motion networks and the city-scale nonlinear time-history analysis, the damage ratios of buildings located in different places can be obtained. The building damage distribution and the human feeling distribution near to different stations are shown in Figure 2 and Figure 3, respectively. These outcomes can provide a reference for post-earthquake rescue work


 

Figure 2 Damage ratio distribution of the buildings near to different stations

 

Figure 3 Human feeling distribution near to different stations


4. Earthquake-induced landslide of the target region subjected to the recorded ground motions

According to local topographic data, lithology data and ground motion records, the distribution of earthquake-induced landslide near to different stations under the different proportions of the landslide slab thickness that is saturated can be calculated, as shown in Figure 4. The basemap shows the distribution of the local slope. The number in the circle represents the critical slope of the landslide. The earthquake-induced landslide tends to occur with a higher probability when the slope is larger than this threshold value.


 

(a) The proportion of the landslide slab thickness that is saturated equals 0%

 

(b) The proportion of the landslide slab thickness that is saturated equals 50%

Figure 4 Distribution of earthquake-induced landslide near to different stations


Scientific background of this report can be found at: http://www.luxinzheng.net/rr.htm


Table 1 Names and locations of the strong motion stations


No. Station Name Latitude Longitude

1 51ZG1 104.75 29.34

2 51ZG2 104.74 29.34

3 51ZG3 104.74 29.34


---End---

相关研究

相关文章,在仿真秀官网搜索

  1. 场地-城市耦合弹塑性分析+神威太湖之光+无人机 | 三项黑科技助力新北川县城震害预测

  2. 新论文:混凝土梁柱子结构连续倒塌动力效应的试验研究

  3. 层间位移角判别准则不适用于剪力墙,怎么办?|新论文:基于曲率的剪力墙损伤评估方法

  4. 新论文:结合BIM和FEMA P-58的建筑地震损失预测方法

  5. 新论文:地震-连续倒塌综合防御组合框架结构体系研究

  6. 新论文:扔砖头、跳盒子,这也是做科学试验哦!| 地震次生坠物情境中的人员疏散模拟

  7. 新论文:改变框架-核心筒结构剪力调整策略对其抗震性能影响的研究

  8. 综述:城市抗震弹塑性分析及其工程应用

  9. 新论文:适用于多LOD BIM的建筑地震损失评估

  10. 新论文:新型地震和连续倒塌综合防御韧性PC框架承载力计算方法

  11. 新论文:角柱失效后平板结构连续倒塌行为实验研究

  12. 新论文:城市建筑群多LOD震害模拟及北京CBD算例

  13. 美国NSF SimCenter+清华城市弹塑性分析=旧金山184万建筑地震模拟

  14. 新论文:受折纸启发的可更换承载-耗能双功能耗能器

  15. 新综述论文:21世纪建筑结构连续倒塌和鲁棒性的研究和实践

  16. 新论文:中柱失效后板柱结构连续倒塌传力机理研究

  17. 新论文:一根钢筋混凝土梁,承载力你能算对么?| 梁的压拱效应计算方法

  18. 新论文:无人机+机器学习+城市弹塑性分析=震后近实时损失预测

  19. 新论文:这个混凝土框架能抗震,能防连续倒塌,还功能可恢复,您不进来看看么?

  20. 新论文:一个好汉三个帮|带端部阻尼器伸臂桁架的抗震性能试验研究

  21. 新论文:BIM+新一代性能化设计=喷淋系统破坏后的地震次生火灾模拟

  22. 新论文:村镇建筑群火灾蔓延模拟与案例

  23. 新论文:建设地震韧性城市所面临的挑战

  24. 新论文:烈焰焚城 | 地震次生火灾的精细化和高真实感模拟

  25. 新论文:城市韧性——基于“三度空间下系统的系统”的思考

  26. 新论文:防屈曲支撑伸臂桁架?几个“狗骨头”可少不了!

  27. 新论文:城市抗震弹塑性分析中如何确定高层建筑的损伤程度?

  28. 新论文:考虑楼板影响的钢筋混凝土框架边柱连续倒塌试验

  29. 新论文:提高地震荷载分项系数,抗震安全性提高了多少?

  30. 新论文:采用减振子结构来控制超高层建筑的地震楼面加速度

  31. 新论文:500m级超高层建筑简化模型及其在结构体系对比中的应用

  32. 606m 超高层建筑OpenSees模型

来源:陆新征课题组
ACT建筑BIM控制试验无人机
著作权归作者所有,欢迎分享,未经许可,不得转载
首次发布时间:2023-03-12
最近编辑:1年前
地震那些事
博士 抗震防灾数值模拟仿真
获赞 52粉丝 56文章 563课程 0
点赞
收藏
未登录
还没有评论
课程
培训
服务
行家
VIP会员 学习计划 福利任务
下载APP
联系我们
帮助与反馈