首页/文章/ 详情

RationalDMIS DMISBasicCommands

1年前浏览2232

DMIS SYNTAX Some DMIS rules

1. DMIS is not case sensitive 


2. Major words 2 to 6 characters, Minor words 1 to 6 characters 

3. Major word may be a DMIS statement or a class of command 


4. All variables are declared , start with a letter should not used , DMIS reserved words.


5. Maximum # of characters per lines is 80 and per statement is 256.


6. Maximum # of characters of the variable name is 16 .




Messages:


Operator message: TEXT/OPER, PLACE SENSOR CLOSE TO LEFT CORNER'


Output file message: TEXT/OUTFIL,' CIRCLE 1'


VARIABLES DECLARATION 


DECL/REAL, AA Declare variable , real data type.


DECL/CHAR, 10, AA Declare variable , Character data type.


DECL/INTGR, AA Declare variable , Integer data type.



Variable Input:


TEXT/QUERY, (AA) , 20, AN, L,' Insert the value of ........'


AN: ALPHANUMERIC response 


A: ALPHABETIC response


 N: NUMERIC response


 L : Left justified response 


R : Right Justified response



1. Arithmetic Operators:


+  Addition=========> WW=ASSIGN/BB+CC


-  Subtraction or Negation =========>WW=ASSIGN/BB-CC


*   Multiplication =========> WW=ASSIGN/BB* CC 


/   Division=========> WW=ASSIGN/BB/CC


* * Exponentiation=======> WW=ASSIGN/((BB-CC) * EE) ** AA)


LOOPING


 DO/index, initial, limit, increment 


              Executable statements 


ENDDO 


Note: index , initial and increment have to be integer variable.

          If the increment is omitted it's value will 1.


Ex:


DECL/REAL, XX, YY, ZZ, DD 


DECL/INTGR, II 


Do/II,1,8,1 

F(CR1)=FEAT/CIRCLE, OUTER, CART, XX, YY, ZZ, 0, 0, 1, DD                                    MEAS/CIRCLE, F (CR1),8 

ENDMES 

ENDDO


CONDITIONAL BRANCHING


IF Conditional  branching: 


 TF/ (loqical expression)


         Executable statement


          ELSE


          Executable statement


ENDIF


OPERATORS 


1. Simple Logical Operators


 EQ.     Equal to ======> IF/(B1. EQ.C1)


 . NE.  Not Equal to ====> IF/(B1. NE.C1)


. LT.    Less Than ========> IF/(B1. LT.C1) 


. LE.   Less Than or Equal to ===> IF/(B1. LE.C1) 


.GT.    Greater Than ========> IF/(B1. GT.C1) 


. GE.    Greater Than or Equal to =======> IF/(B1. GE.C1)



 2. Compound Logical Operators 


. AND. will be true if both operands are true 


. OR. will be true if either one operand is true.


. NOT. will be true if the operand is false.


SELECT Conditional branching:


SELECT/ arg


CASE/arg1


Executable statement


ENDCAS


CASE/ arg2


Executable statement


ENDCAS


DFTCAS


Executable statement


ENDCAS


ENDSEL



OBTAIN


DECL/REAL,X1, Y1, Z1 


DECL/INTGR, II


 f (pt1)=feat/point,cart, 0,0,0,0, 0, 1


 meas/point, f (pt1), 1 


endmes 


X1 = obtain/fa (pt1),3 


Y 1= obtain/fa (pt1) ,4


 Z1= obtain/fa (pt1), 5


EVAL 


Note: Where tolerance apply , OBTAIN will evaluate the tolerance statement in the last EVAL and /or OUTPUT command.


DECL/REAL, AA 


T (DTB1) = TOL/DISTB, NOMINL, 35.000000,0.000000, 0.000000, XAXIS, AVG EVAL/FA (CR1), FA (CR3), T (DTB1)


 AA=OBTAIN/TA (DTB1), 4


VALUE 


Assign a measurement or calculation result to a variable.


Example:


$s---MEASURING AND TOLERANCING A FEATURE CIRCLE --------

F(CR1) = FEAT/CIRCLE, INNER, CART, 101, 102, 103, 0, 0,1, 41 

MEAS/CIRCLE, F(CR1), 3 


PTMEAS/CART, 93.704, 121.158, 103.000, 0.356, -0.935, 0.000 


PTMEAS/CART, 88.057, 86.103, 103.000, 0.631, 0.775, 0.000 


PTMEAS/CART, 121.239, 98.739, 103.000, -0.987, 0.159, 0.000 


ENDMES 


T (TOLX) =TOL/CORTOL, XAXIS, -0.200, 0.200 


T(TOLY) = TOL/CORTOL, YAXIS, -0.300, 0.300


T (TOLZ) =TOL/CORTOL, ZAXIS, -0.400, 0.400 , 


T (TOLDIAM)  TOL/DIAM, -0.500, 0.50 


DECL/REAL, RLDEV, RLACT, RLAMT, RLSIZE, DDIAM, DDIST 

DECL/INTGR, INTOOT 


DDIAM=VALUE/FA (CR1), SIZE       $$ Assign the diameter value of CR1 to the 


variable DDIAM 


T(DTB2) TOL/DISTB, NOMINL, 200.000000,-0.010000, 0.010000, XAXIS, AVG EVAL/FA (CR1), FA (CR2) ,T (DTB2) 


DDIS-VALUE/TA (DTB2) , ACT     $$ Assign the distance actual between CR:


and CR2 to variable DDIST



$s This command will evaluate the feature (CR1) according to the

 tolerance (TOLX) specified before.

EVAL/FA (CR1) , T (TOLX)

 ss this command will assign the value of the deviation to a variable 

RLDEV=VALUE/TA (TOLX) , DEV

 $s this command will assign the value of out of tolerance to a 

variable 

RLAMT=VALUE/TA (TOLX), AMT

 $ş this command will return the value 1 if x of (CR1) is in tolerance 

and o if it is out of tolerance

 INTOOT-VALUE/TA (TOLX) , INTOL 

$$  P.S. : the variable INTOOT has to be declared as INTEGER because


 it will have the value o or 1 only


MACRO 


MACRO DEFINTITION 

M (TEST)-MACRO/X1, Y1, Z1, I, J, K, 'LABEL'

 F (LABEL)-FEAT/POINT, CART, X1, Y1, Z1, I,J, k 

MEAS/POINT, F (LABEL), 1 

PTMEAS/CART,X1,Y1, Z1,I,J, K 

ENDMES 

ENDMAC 

CALL INTERNAL MACRO:

CALL/M (TEST) , 200, 100, 200, 0, 0, 1, (POINT1)



DECLARATION OF EXTERNAL FILE:


XTERN EXTFIL/DMIS, 'C:\ DMIS\ TEST. dms'

..

ENDXTN CALL MACRO FROM EXTERNAL DMIS FILE:


CALL/EXTERN, DMIS, M (TEST1) CALL EXTERNAL SYSTEM FIIE:


CALL/EXTERN, SYS, '/WINDOWS/PBRUSH. EXE C:\ CAD\175. 

BMP'


DIRECT READ AND WRITE FROM FILE 


DID (CAP) =DEVICE/STOR, 'C:\ IVAN\ TT. TXT'


DECL/REAL,X1, X2 


DECL/INTGR, NN 


OPEN/DID (CAP), DIRECT, OUTPUT, APPEND WRITE/DID (CAP),X1,X2, NN 


OPEN/DID (CAP), DIRECT, INPUT, APPEND READ/DID (CAP),X1,X2, NN


LOADING SENSOR DATA BASE FROM THE PROGRAM


 DID (SNSBASE)=DEVICE/STOR, 'C:\ Vms \ Users\ YOUR LOGIN NAME\ sensor\ YOUR 


PROJECT NAME WHERE SENSORS EXIST. sns'


OPEN/DID(SNSBASE),SNS 


LOADING COORDINATE REFERENCE SYSTEMS DATA BASE FROM THE PROGRAM 


DID (BASE) =DEVICE/STOR, 'c:\ AA\ COORD\ TEST. CRD'


OPEN/DID (BASE), PCS



DMIS INTRINSIC FUNCTIONS

来源:RationalDMIS测量技术
ACTUM
著作权归作者所有,欢迎分享,未经许可,不得转载
首次发布时间:2023-07-01
最近编辑:1年前
山涧果子
大专 签名征集中
获赞 203粉丝 48文章 1203课程 0
点赞
收藏
未登录
还没有评论
课程
培训
服务
行家
VIP会员 学习 福利任务 兑换礼品
下载APP
联系我们
帮助与反馈